Skip Ribbon Commands
Skip to main content
Sign In
Careers Contact Live Chat

Permit Application

​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​

 

 

Precision Heat Treat Ltd.Precision Heat Treat Ltd.GVA1267<div class="ExternalClass212866AB93B3430E8CB9F9AC488284B5"><p>​The purpose of this application is to request authorization to discharge air contaminants from a steel heat treating facility located at 9531 194A Street, Surrey, BC V4N 4G4. </p><p>Precision Heat Treat Ltd. requests authorization to discharge air contaminants from a steel heat treating facility where parts are loaded into the Integral Quench (IQ) furnaces to reach the maximum desirable hardness. Quenching oil is used to cool the metal parts after heat application. After removing from the IQ furnace and passing through the carburizing furnace, the parts are washed and introduced to the tempering furnace several time to achieve the desired product specification. In some stages, inert gases (N2) or reducing gases (e.g., ammonia during carburizing) are added to the furnace to remove surface contaminants/impurities and achieve specific surface characteristics. ​<br></p></div>9531 194A Street, Surrey, BC V4N 4G4https://maps.app.goo.gl/tWqNaqvQRrk6r4cQ8, 9531 194A Street, Surrey, BC V4N 4G4Application Under Review<div class="ExternalClass6CCC0BC159764BE586B0705746EDAA06"><h3>​Public Notification<br></h3><p>A person who may be adversely affected by the granting of a permit or approval, or by the granting of an amendment to a permit or approval may, within 30 days, notify the District Director in writing stating how that person is affected. <br></p><div class="ExternalClassFC0A75DEB66E44CB856B38D73B3A9AC0"><p>When making a decision on the permit or approval application, the District Director will consider the application, c​omments submitted and any responses provided by the applicant.  If you wish to be notified of the District Director's decision, please provide either a valid email or postal address.<br></p><h3>Freedom of Information and Protection of Privacy<br></h3><p>For the project described on this webpage, the information collected by whatever means, such as web form, email or post, during the comment period and the time following until a decision on the permit application has been made is collected by Metro Vancouver in accordance to s.26(c) of the Freedom of Information and Protection of Privacy Act. The information collected will be used for the purpose of making a decision on the permit application and will be forwarded to the permit applicant for response to the District Director. By submitting a public comment, you consent to such disclosure.  Also, your submission may be made available to the public as part of the public record, subject to the provisions of the Freedom of Information and Protection of Privacy Act.​<br></p></div></div><div class="ExternalClassC959792E72CF4856BD17F6AD90BEEBE0"><p>​If you have any questions about the collection or use of this personal information, please contact the Privacy Officer at privacy@metrovancouver.org<br></p></div>PrecisionHeatTreatComments@metrovancouver.org<div class="ExternalClassDACDBE4B22344258A920176998ABE31E"><p>​District Director<br>4515 Central Boulevard<br>Burnaby, BC, V5H 0C6​<br></p></div>1https://precisionheattreat.com, https://precisionheattreat.com

 Documents

 

 

2024-09-16 - Environmental Protection Notice - Precision Heat Treat Ltd. - 1267https://metrovancouver.org/services/environmental-regulation-enforcement/air-quality-regulatory-program/PermitApplicationDocuments/2024-09-16 - Environmental Protection Notice - Precision Heat Treat Ltd. - 1267.pdf2024-09-16 - Environmental Protection Notice - Precision Heat Treat Ltd. - 1267

This website uses cookies to ensure you get the best experience. By continuing to use this site, you accept our use of cookies. View our privacy statement.